Procedure for the LEC-220C Converter 

Operating Guide - Read the complete instructions and safety information supplied with the LEC-220C Power Tap before use.

LEC-220C Power Converter tester1. Test 110/120 volt outlets with outlet tester supplied with LEC-220C Power Tap to make sure the outlet is wired correctly and does not have a ground fault interrupter in the circuit.


2.  Plug one of the LEC-220C Power Tap's cords into a 110/120 volt 20 amp outlet without ground fault interrupters in the circuits. When running the Eliminator 3000-220 it must be a 20 amp circuit.
LEC-220C Power Converter










3. Plug the other power cord into a different  20 amp outlet without ground fault interrupters in the circuits, using an extension cord of appropriate length. When running the Eliminator 3000-220 it must be a 20 amp circuit.
LEC-220C Power Converter

4. The amber lamp on the front cover will light when connection is made to an outlet on an independent circuit.  If the lamp doesn't light, try different outlets until it does.  (Technically, an "independent" circuit is one that is 180 degrees out of phase with the first.  In practice, LEC-220C systems automatically test for this.  No special knowledge or action is required by the user.)
LEC-220C Power Converter

#LEC-220C  $ 220.00 includes
(1) Power Module 20 amp, 4400 watts with NEMA L6-20 locking outlet
LEC-220C Power Converter plug
(2) Adapters - 5-15P to 5-20R
(1) Outlet Tester



Specifications for LEC-220C Power Tap 

INPUT:

Voltage:  108 to 125 Volts AC, 60 HZ, non-GFI circuits, two circuits, out of phase

Two 36 inch power cords, 20 amperes each line, NEMA 5-20 plugs

OUTPUT VOLTAGE

Single Phase Input: 216 to 250 Volts AC (2 times input voltage)

Three Phase Input: 187 to 216 Volts AC (1.732 times input voltage)

OUTPUT POWER:   

4400 watts continuous; 22,000 watts peak, typical at 220 volts.

OUTPUT CURRENT:

20 amps continuous

OUTPUT RECEPTACLE:


Locking, single, NEMA L6-20R

POWER CONSUMPTION:   8 watts, plus equipment connected

SIZE: 2.7 pounds, Approximately 6-1/2 inches x 5 inches x 3 inches

ENVIRONMENT:

35 to 95 degrees F, 85% relative humidity, max., non-condensing.

No explosive gases, dust or other materials.

Dry.  Away from water, oils or other liquids.

Avoid excessive dust.

LIMITED WARRANTY:  One year, see warranty page for full text.